B900C7FF
[IBS Home] [Up] [10111024] [A6xx0255] [A6xx0266] [A6xx0277] [B900C7FF] [D6xx]

IBM Server Site

IBS Home Up

 

 

SRC Reference B900C7FF

SI16941 - IPL-SRCB90037FF QSYCHGSP fails during IPL

PTF ( Program Temporary Fixes ) Cover letter

Abstract

IPL-SRCB90037FF QSYCHGSP fails during IPL
 

Pre/Co-Requisite PTF / Fix List


REQ  LICENSED      PTF/FIX  LEVEL
TYPE PROGRAM  REL  NUMBER   MIN/MAX  OPTION
---- -------- ---  -------  -------  ------
CO   5722SS1  530  SI16940   00/00    0000



NOTICE:
-------
   Application of this PTF may disable or render ineffective programs that
   use system memory addresses not generated by the IBM translator,
   including programs that circumvent control technology designed to limit
   interactive capacity to purchased levels.  This PTF may be a prerequisite
   for future PTFs.  By applying this PTF you authorize and agree to the
   foregoing.

   This PTF is subject to the terms of the license agreement which
   accompanied, or was contained in, the Program for which you are obtaining
   the PTF.  You are not authorized to install or use the PTF except as part
   of a Program for which you have a valid Proof of Entitlement.

   SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
   AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
   AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
   INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
   MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
   REGARDING THE PTF.

   The applicable license agreement may have been provided to you in printed
   form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
   CL command.



 

APAR Error Description / Circumvention

DESCRIPTION OF PROBLEM FIXED FOR APAR SE18773 :
-----------------------------------------------
   Using the DST option to reset the QSECOFR password causes a
   failure during IPL.  The reference code data contains:
   B90037FF
   0DB00080
   20200010
   D8E2E8C3
   C8C7E2D7
   40400340
   C3D7C6F2
   F5F2F400
   Indicating message CPF2524 occurred in QSYCHGSP.

CORRECTION FOR APAR SE18773 :
-----------------------------
   The IPL program calling QSYCHGSP will be changed
   to correct the problem.

CIRCUMVENTION FOR APAR SE18773 :
--------------------------------
   None.
 

Activation Instructions


   None.
 

Special Instructions


   If this PTF is applied as a delayed PTF, the DST option to reset the Ope
   rating system QSECOFR password should not be used until after the IPL to
    apply this PTF.

   ********************************************************************
   THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
   PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
   IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
   ********************************************************************

   SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI14089 :
   =================================================

   The system should be IPLed after this PTF is applied to fix the problem.
 

Default Instructions

   THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.

 

Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI14349      OSP-SRCC9002C10 hang during IPL
   SI14089      OSP-INCORROUT START PROBLEM LOGGING UNTIL QSYSWRK STARTS

Summary Information

System.............................................. iSeries
Models..............................................  
Release............................................ V5R3M0
Recompile........................................ N
Library................................................ QSYS
MRI Feature...................................... NONE
Cum Level...................................... C5032530

 

System i Support

 
IBS Lumber and Building Material Software  Copyright © 2006 IBS Lumber Software Inc (TM)
Last modified: December 5, 2008

IBS Sales & Support (888) 427-1566
Main Office 1-812-547-4640
Fax IBS  1-812-547-9614

IBS Corporation - Building Materials Software for your Lumberyard

All pages contained in this support website are not intended for general public distribution.  Any material here can be considered private, confidential with various copyrights and restrictions against public release.  You 'the browser' cannot legally release this information for general public distribution.

IBS Webmail | IBS Corporate Site | IBS Homepage
remote support:
http://www.gotomeeting.com | remote support download program